You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
85 lines
3.0 KiB
85 lines
3.0 KiB
#pragma once |
|
|
|
#include "AP_Baro_Backend.h" |
|
|
|
#ifndef AP_BARO_ICP201XX_ENABLED |
|
#define AP_BARO_ICP201XX_ENABLED AP_BARO_BACKEND_DEFAULT_ENABLED |
|
#endif |
|
|
|
#if AP_BARO_ICP201XX_ENABLED |
|
|
|
#include <AP_HAL/AP_HAL.h> |
|
#include <AP_HAL/Semaphores.h> |
|
#include <AP_HAL/Device.h> |
|
|
|
class AP_Baro_ICP201XX : public AP_Baro_Backend |
|
{ |
|
public: |
|
void update() override; |
|
|
|
static AP_Baro_Backend *probe(AP_Baro &baro, AP_HAL::OwnPtr<AP_HAL::I2CDevice> dev); |
|
|
|
private: |
|
AP_Baro_ICP201XX(AP_Baro &baro, AP_HAL::OwnPtr<AP_HAL::I2CDevice> dev); |
|
|
|
bool init(); |
|
void dummy_reg(); |
|
bool read_reg(uint8_t reg, uint8_t *buf, uint8_t len); |
|
bool read_reg(uint8_t reg, uint8_t *val); |
|
bool write_reg(uint8_t reg, uint8_t val); |
|
bool mode_select(uint8_t mode); |
|
bool read_otp_data(uint8_t addr, uint8_t cmd, uint8_t *val); |
|
bool get_sensor_data(float *pressure, float *temperature); |
|
void soft_reset(); |
|
bool boot_sequence(); |
|
bool configure(); |
|
void wait_read(); |
|
bool flush_fifo(); |
|
void timer(); |
|
|
|
uint8_t instance; |
|
|
|
AP_HAL::OwnPtr<AP_HAL::I2CDevice> dev; |
|
|
|
// accumulation structure, protected by _sem |
|
struct { |
|
float tsum; |
|
float psum; |
|
uint32_t count; |
|
} accum; |
|
|
|
// time last read command was sent |
|
uint32_t last_measure_us; |
|
|
|
enum class OP_MODE : uint8_t { |
|
OP_MODE0 = 0, /* Mode 0: Bw:6.25 Hz ODR: 25Hz */ |
|
OP_MODE1, /* Mode 1: Bw:30 Hz ODR: 120Hz */ |
|
OP_MODE2, /* Mode 2: Bw:10 Hz ODR: 40Hz */ |
|
OP_MODE3, /* Mode 3: Bw:0.5 Hz ODR: 2Hz */ |
|
OP_MODE4, /* Mode 4: User configurable Mode */ |
|
} _op_mode{OP_MODE::OP_MODE2}; |
|
|
|
enum class FIFO_READOUT_MODE : uint8_t { |
|
FIFO_READOUT_MODE_PRES_TEMP = 0, /* Pressure and temperature as pair and address wraps to the start address of the Pressure value ( pressure first ) */ |
|
FIFO_READOUT_MODE_TEMP_ONLY = 1, /* Temperature only reporting */ |
|
FIFO_READOUT_MODE_TEMP_PRES = 2, /* Pressure and temperature as pair and address wraps to the start address of the Temperature value ( Temperature first ) */ |
|
FIFO_READOUT_MODE_PRES_ONLY = 3 /* Pressure only reporting */ |
|
} _fifo_readout_mode{FIFO_READOUT_MODE::FIFO_READOUT_MODE_PRES_TEMP}; |
|
|
|
enum class POWER_MODE : uint8_t { |
|
POWER_MODE_NORMAL = 0, /* Normal Mode: Device is in standby and goes to active mode during the execution of a measurement */ |
|
POWER_MODE_ACTIVE = 1 /* Active Mode: Power on DVDD and enable the high frequency clock */ |
|
} _power_mode{POWER_MODE::POWER_MODE_NORMAL}; |
|
|
|
enum MEAS_MODE : uint8_t { |
|
MEAS_MODE_FORCED_TRIGGER = 0, /* Force trigger mode based on icp201xx_forced_meas_trigger_t **/ |
|
MEAS_MODE_CONTINUOUS = 1 /* Continuous measurements based on selected mode ODR settings*/ |
|
} _meas_mode{MEAS_MODE::MEAS_MODE_CONTINUOUS}; |
|
|
|
enum FORCED_MEAS_TRIGGER : uint8_t { |
|
FORCE_MEAS_STANDBY = 0, /* Stay in Stand by */ |
|
FORCE_MEAS_TRIGGER_FORCE_MEAS = 1 /* Trigger for forced measurements */ |
|
} _forced_meas_trigger{FORCED_MEAS_TRIGGER::FORCE_MEAS_STANDBY}; |
|
}; |
|
|
|
#endif // AP_BARO_ICP201XX_ENABLED
|