You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
293 lines
12 KiB
293 lines
12 KiB
#pragma once |
|
|
|
#include <AP_Common/AP_Common.h> |
|
#include <AP_Param/AP_Param.h> |
|
#include <AP_Math/AP_Math.h> |
|
#include <GCS_MAVLink/GCS_MAVLink.h> |
|
#include "AP_BattMonitor_Params.h" |
|
|
|
// maximum number of battery monitors |
|
#ifndef AP_BATT_MONITOR_MAX_INSTANCES |
|
#define AP_BATT_MONITOR_MAX_INSTANCES 9 |
|
#endif |
|
|
|
// first monitor is always the primary monitor |
|
#define AP_BATT_PRIMARY_INSTANCE 0 |
|
|
|
#define AP_BATT_SERIAL_NUMBER_DEFAULT -1 |
|
|
|
#define AP_BATT_MONITOR_TIMEOUT 5000 |
|
|
|
#define AP_BATT_MONITOR_RES_EST_TC_1 0.5f |
|
#define AP_BATT_MONITOR_RES_EST_TC_2 0.1f |
|
|
|
#if !HAL_MINIMIZE_FEATURES && BOARD_FLASH_SIZE > 1024 |
|
#define AP_BATT_MONITOR_CELLS_MAX 14 |
|
#else |
|
#define AP_BATT_MONITOR_CELLS_MAX 12 |
|
#endif |
|
|
|
#ifndef AP_BATTMON_SMBUS_ENABLE |
|
#define AP_BATTMON_SMBUS_ENABLE 1 |
|
#endif |
|
|
|
#ifndef AP_BATTMON_FUELFLOW_ENABLE |
|
#define AP_BATTMON_FUELFLOW_ENABLE (BOARD_FLASH_SIZE > 1024) |
|
#endif |
|
|
|
#ifndef AP_BATTMON_FUELLEVEL_PWM_ENABLE |
|
#define AP_BATTMON_FUELLEVEL_PWM_ENABLE (BOARD_FLASH_SIZE > 1024) |
|
#endif |
|
|
|
#ifndef AP_BATTMON_FUELLEVEL_ANALOG_ENABLE |
|
#define AP_BATTMON_FUELLEVEL_ANALOG_ENABLE (BOARD_FLASH_SIZE > 1024) |
|
#endif |
|
|
|
// declare backend class |
|
class AP_BattMonitor_Backend; |
|
class AP_BattMonitor_Analog; |
|
class AP_BattMonitor_SMBus; |
|
class AP_BattMonitor_SMBus_Solo; |
|
class AP_BattMonitor_SMBus_Generic; |
|
class AP_BattMonitor_SMBus_Maxell; |
|
class AP_BattMonitor_SMBus_Rotoye; |
|
class AP_BattMonitor_UAVCAN; |
|
class AP_BattMonitor_Generator; |
|
class AP_BattMonitor_INA2XX; |
|
class AP_BattMonitor_LTC2946; |
|
class AP_BattMonitor_Torqeedo; |
|
class AP_BattMonitor_FuelLevel_Analog; |
|
|
|
class AP_BattMonitor |
|
{ |
|
friend class AP_BattMonitor_Backend; |
|
friend class AP_BattMonitor_Analog; |
|
friend class AP_BattMonitor_SMBus; |
|
friend class AP_BattMonitor_SMBus_Solo; |
|
friend class AP_BattMonitor_SMBus_Generic; |
|
friend class AP_BattMonitor_SMBus_Maxell; |
|
friend class AP_BattMonitor_SMBus_Rotoye; |
|
friend class AP_BattMonitor_UAVCAN; |
|
friend class AP_BattMonitor_Sum; |
|
friend class AP_BattMonitor_FuelFlow; |
|
friend class AP_BattMonitor_FuelLevel_PWM; |
|
friend class AP_BattMonitor_Generator; |
|
friend class AP_BattMonitor_INA2XX; |
|
friend class AP_BattMonitor_LTC2946; |
|
|
|
friend class AP_BattMonitor_Torqeedo; |
|
friend class AP_BattMonitor_FuelLevel_Analog; |
|
|
|
public: |
|
|
|
// battery failsafes must be defined in levels of severity so that vehicles wont fall backwards |
|
enum class Failsafe : uint8_t { |
|
None = 0, |
|
Low, |
|
Critical |
|
}; |
|
|
|
// Battery monitor driver types |
|
enum class Type { |
|
NONE = 0, |
|
ANALOG_VOLTAGE_ONLY = 3, |
|
ANALOG_VOLTAGE_AND_CURRENT = 4, |
|
SOLO = 5, |
|
BEBOP = 6, |
|
SMBus_Generic = 7, |
|
UAVCAN_BatteryInfo = 8, |
|
BLHeliESC = 9, |
|
Sum = 10, |
|
FuelFlow = 11, |
|
FuelLevel_PWM = 12, |
|
SUI3 = 13, |
|
SUI6 = 14, |
|
NeoDesign = 15, |
|
MAXELL = 16, |
|
GENERATOR_ELEC = 17, |
|
GENERATOR_FUEL = 18, |
|
Rotoye = 19, |
|
// 20 was MPPT_PacketDigital |
|
INA2XX = 21, |
|
LTC2946 = 22, |
|
Torqeedo = 23, |
|
FuelLevel_Analog = 24, |
|
}; |
|
|
|
FUNCTOR_TYPEDEF(battery_failsafe_handler_fn_t, void, const char *, const int8_t); |
|
|
|
AP_BattMonitor(uint32_t log_battery_bit, battery_failsafe_handler_fn_t battery_failsafe_handler_fn, const int8_t *failsafe_priorities); |
|
|
|
/* Do not allow copies */ |
|
AP_BattMonitor(const AP_BattMonitor &other) = delete; |
|
AP_BattMonitor &operator=(const AP_BattMonitor&) = delete; |
|
|
|
static AP_BattMonitor *get_singleton() { |
|
return _singleton; |
|
} |
|
|
|
// cell voltages in millivolts |
|
struct cells { |
|
uint16_t cells[AP_BATT_MONITOR_CELLS_MAX]; |
|
}; |
|
|
|
// The BattMonitor_State structure is filled in by the backend driver |
|
struct BattMonitor_State { |
|
cells cell_voltages; // battery cell voltages in millivolts, 10 cells matches the MAVLink spec |
|
float voltage; // voltage in volts |
|
float current_amps; // current in amperes |
|
float consumed_mah; // total current draw in milliamp hours since start-up |
|
float consumed_wh; // total energy consumed in Wh since start-up |
|
uint32_t last_time_micros; // time when voltage and current was last read in microseconds |
|
uint32_t low_voltage_start_ms; // time when voltage dropped below the minimum in milliseconds |
|
uint32_t critical_voltage_start_ms; // critical voltage failsafe start timer in milliseconds |
|
float temperature; // battery temperature in degrees Celsius |
|
uint32_t temperature_time; // timestamp of the last received temperature message |
|
float voltage_resting_estimate; // voltage with sag removed based on current and resistance estimate in Volt |
|
float resistance; // resistance, in Ohms, calculated by comparing resting voltage vs in flight voltage |
|
Failsafe failsafe; // stage failsafe the battery is in |
|
bool healthy; // battery monitor is communicating correctly |
|
bool is_powering_off; // true when power button commands power off |
|
bool powerOffNotified; // only send powering off notification once |
|
uint32_t time_remaining; // remaining battery time |
|
bool has_time_remaining; // time_remaining is only valid if this is true |
|
const struct AP_Param::GroupInfo *var_info; |
|
}; |
|
|
|
static const struct AP_Param::GroupInfo *backend_var_info[AP_BATT_MONITOR_MAX_INSTANCES]; |
|
|
|
// Return the number of battery monitor instances |
|
uint8_t num_instances(void) const { return _num_instances; } |
|
|
|
// detect and initialise any available battery monitors |
|
void init(); |
|
|
|
/// Read the battery voltage and current for all batteries. Should be called at 10hz |
|
void read(); |
|
|
|
// healthy - returns true if monitor is functioning |
|
bool healthy(uint8_t instance) const; |
|
|
|
// return true if all configured battery monitors are healthy |
|
bool healthy() const; |
|
|
|
/// voltage - returns battery voltage in volts |
|
float voltage(uint8_t instance) const; |
|
float voltage() const { return voltage(AP_BATT_PRIMARY_INSTANCE); } |
|
|
|
// voltage for a GCS, may be resistance compensated |
|
float gcs_voltage(uint8_t instance) const; |
|
float gcs_voltage(void) const { return gcs_voltage(AP_BATT_PRIMARY_INSTANCE); } |
|
|
|
/// get voltage with sag removed (based on battery current draw and resistance) |
|
/// this will always be greater than or equal to the raw voltage |
|
float voltage_resting_estimate(uint8_t instance) const; |
|
float voltage_resting_estimate() const { return voltage_resting_estimate(AP_BATT_PRIMARY_INSTANCE); } |
|
|
|
/// current_amps - returns the instantaneous current draw in amperes |
|
bool current_amps(float ¤t, const uint8_t instance = AP_BATT_PRIMARY_INSTANCE) const WARN_IF_UNUSED; |
|
|
|
/// consumed_mah - returns total current drawn since start-up in milliampere.hours |
|
bool consumed_mah(float &mah, const uint8_t instance = AP_BATT_PRIMARY_INSTANCE) const WARN_IF_UNUSED; |
|
|
|
/// consumed_wh - returns total energy drawn since start-up in watt.hours |
|
bool consumed_wh(float&wh, const uint8_t instance = AP_BATT_PRIMARY_INSTANCE) const WARN_IF_UNUSED; |
|
|
|
/// capacity_remaining_pct - returns true if the percentage is valid and writes to percentage argument |
|
virtual bool capacity_remaining_pct(uint8_t &percentage, uint8_t instance) const WARN_IF_UNUSED; |
|
bool capacity_remaining_pct(uint8_t &percentage) const WARN_IF_UNUSED { return capacity_remaining_pct(percentage, AP_BATT_PRIMARY_INSTANCE); } |
|
|
|
/// time_remaining - returns remaining battery time |
|
bool time_remaining(uint32_t &seconds, const uint8_t instance = AP_BATT_PRIMARY_INSTANCE) const WARN_IF_UNUSED; |
|
|
|
/// pack_capacity_mah - returns the capacity of the battery pack in mAh when the pack is full |
|
int32_t pack_capacity_mah(uint8_t instance) const; |
|
int32_t pack_capacity_mah() const { return pack_capacity_mah(AP_BATT_PRIMARY_INSTANCE); } |
|
|
|
/// returns true if a battery failsafe has ever been triggered |
|
bool has_failsafed(void) const { return _has_triggered_failsafe; }; |
|
|
|
/// returns the highest failsafe action that has been triggered |
|
int8_t get_highest_failsafe_priority(void) const { return _highest_failsafe_priority; }; |
|
|
|
/// get_type - returns battery monitor type |
|
enum Type get_type() const { return get_type(AP_BATT_PRIMARY_INSTANCE); } |
|
enum Type get_type(uint8_t instance) const { |
|
return (Type)_params[instance]._type.get(); |
|
} |
|
|
|
/// get_serial_number - returns battery serial number |
|
int32_t get_serial_number() const { return get_serial_number(AP_BATT_PRIMARY_INSTANCE); } |
|
int32_t get_serial_number(uint8_t instance) const { |
|
return _params[instance]._serial_number; |
|
} |
|
|
|
/// true when (voltage * current) > watt_max |
|
bool overpower_detected() const; |
|
bool overpower_detected(uint8_t instance) const; |
|
|
|
// cell voltages in millivolts |
|
bool has_cell_voltages() const { return has_cell_voltages(AP_BATT_PRIMARY_INSTANCE); } |
|
bool has_cell_voltages(const uint8_t instance) const; |
|
const cells &get_cell_voltages() const { return get_cell_voltages(AP_BATT_PRIMARY_INSTANCE); } |
|
const cells &get_cell_voltages(const uint8_t instance) const; |
|
|
|
// temperature |
|
bool get_temperature(float &temperature) const { return get_temperature(temperature, AP_BATT_PRIMARY_INSTANCE); } |
|
bool get_temperature(float &temperature, const uint8_t instance) const; |
|
|
|
// cycle count |
|
bool get_cycle_count(uint8_t instance, uint16_t &cycles) const; |
|
|
|
// get battery resistance estimate in ohms |
|
float get_resistance() const { return get_resistance(AP_BATT_PRIMARY_INSTANCE); } |
|
float get_resistance(uint8_t instance) const { return state[instance].resistance; } |
|
|
|
// returns false if we fail arming checks, in which case the buffer will be populated with a failure message |
|
bool arming_checks(size_t buflen, char *buffer) const; |
|
|
|
// sends powering off mavlink broadcasts and sets notify flag |
|
void checkPoweringOff(void); |
|
|
|
// reset battery remaining percentage |
|
bool reset_remaining_mask(uint16_t battery_mask, float percentage); |
|
bool reset_remaining(uint8_t instance, float percentage) { return reset_remaining_mask(1U<<instance, percentage);} |
|
|
|
// Returns mavlink charge state |
|
MAV_BATTERY_CHARGE_STATE get_mavlink_charge_state(const uint8_t instance) const; |
|
|
|
// Returns mavlink fault state |
|
uint32_t get_mavlink_fault_bitmask(const uint8_t instance) const; |
|
|
|
static const struct AP_Param::GroupInfo var_info[]; |
|
|
|
protected: |
|
|
|
/// parameters |
|
AP_BattMonitor_Params _params[AP_BATT_MONITOR_MAX_INSTANCES]; |
|
|
|
private: |
|
static AP_BattMonitor *_singleton; |
|
|
|
BattMonitor_State state[AP_BATT_MONITOR_MAX_INSTANCES]; |
|
AP_BattMonitor_Backend *drivers[AP_BATT_MONITOR_MAX_INSTANCES]; |
|
uint32_t _log_battery_bit; |
|
uint8_t _num_instances; /// number of monitors |
|
|
|
void convert_dynamic_param_groups(uint8_t instance); |
|
|
|
/// returns the failsafe state of the battery |
|
Failsafe check_failsafe(const uint8_t instance); |
|
void check_failsafes(void); // checks all batteries failsafes |
|
|
|
battery_failsafe_handler_fn_t _battery_failsafe_handler_fn; |
|
const int8_t *_failsafe_priorities; // array of failsafe priorities, sorted highest to lowest priority, -1 indicates no more entries |
|
|
|
int8_t _highest_failsafe_priority; // highest selected failsafe action level (used to restrict what actions we move into) |
|
bool _has_triggered_failsafe; // true after a battery failsafe has been triggered for the first time |
|
|
|
}; |
|
|
|
namespace AP { |
|
AP_BattMonitor &battery(); |
|
};
|
|
|