#include "AP_BattMonitor_Generator.h" |
|
|
|
#if HAL_GENERATOR_ENABLED |
|
|
|
#include <AP_Common/AP_Common.h> |
|
#include <AP_Math/AP_Math.h> |
|
|
|
extern const AP_HAL::HAL& hal; |
|
|
|
/* |
|
Fuel class |
|
*/ |
|
// This is where we tell the battery monitor 'we have current' if we want to report a fuel level remaining |
|
bool AP_BattMonitor_Generator_FuelLevel::has_current(void) const |
|
{ |
|
// If the generator has fuel remaining we must also state that we have current |
|
return has_consumed_energy(); |
|
} |
|
|
|
// This is where we tell the battery monitor 'we have consummed energy' if we want to report a fuel level remaining |
|
bool AP_BattMonitor_Generator_FuelLevel::has_consumed_energy(void) const |
|
{ |
|
// Get pointer to generator singleton |
|
AP_Generator *generator = AP::generator(); |
|
|
|
if (generator == nullptr) { |
|
return false; |
|
} |
|
|
|
// Use consumed_mAh in BattMonitor to display fuel remaining |
|
return generator->has_fuel_remaining(); |
|
} |
|
|
|
void AP_BattMonitor_Generator_FuelLevel::init() |
|
{ |
|
// Set params for users: |
|
// Fuel level is only reported as a percentage |
|
_params._pack_capacity.set(100); |
|
// Fuel only reports a fixed 1v, don't want batt monitor failsafes on this instance |
|
_params._low_voltage.set(0); |
|
_params._critical_voltage.set(0); |
|
} |
|
|
|
// Read the fuel level. Should be called at 10hz |
|
void AP_BattMonitor_Generator_FuelLevel::read() |
|
{ |
|
_state.healthy = false; |
|
|
|
// Get pointer to generator singleton |
|
AP_Generator *generator = AP::generator(); |
|
|
|
// Not healthy if we can't find a generator |
|
if (generator == nullptr) { |
|
return; |
|
} |
|
|
|
if (!generator->healthy()) { |
|
return; |
|
} |
|
|
|
// As this is a battery monitor instance report voltage |
|
// Report fixed voltage of 1V |
|
_state.voltage = 1.0f; |
|
|
|
// This is a bodge to display tank level as a percentage on GCS. Users should set _params.pack_capacity == 100 to get a clear percentage in GCS |
|
_state.consumed_mah = (1 - generator->get_fuel_remain()) * _params._pack_capacity.get(); |
|
|
|
// If we got this far then must be healthy |
|
_state.healthy = true; |
|
_state.last_time_micros = AP_HAL::micros(); |
|
} |
|
|
|
/* |
|
Electrical class |
|
*/ |
|
bool AP_BattMonitor_Generator_Elec::has_current(void) const |
|
{ |
|
// Get pointer to generator singleton |
|
AP_Generator *generator = AP::generator(); |
|
|
|
if (generator == nullptr) { |
|
return false; |
|
} |
|
|
|
return generator->has_current(); |
|
} |
|
|
|
bool AP_BattMonitor_Generator_Elec::has_consumed_energy(void) const |
|
{ |
|
// Get pointer to generator singleton |
|
AP_Generator *generator = AP::generator(); |
|
|
|
if (generator == nullptr) { |
|
return false; |
|
} |
|
|
|
return generator->has_consumed_energy(); |
|
} |
|
|
|
// Read the electrical measurements from the generator |
|
void AP_BattMonitor_Generator_Elec::read() |
|
{ |
|
_state.healthy = false; |
|
|
|
// Get pointer to generator singleton |
|
AP_Generator *generator = AP::generator(); |
|
|
|
// Not healthy if we can't find a generator |
|
if (generator == nullptr) { |
|
return; |
|
} |
|
|
|
if (!generator->healthy()) { |
|
return; |
|
} |
|
|
|
// Update readings |
|
_state.voltage = generator->get_voltage(); |
|
|
|
_state.current_amps = generator->get_current(); |
|
|
|
// Always reset consumed value, integration is done in AP_Generator library |
|
_state.consumed_mah = generator->get_batt_consumed(); |
|
_state.consumed_wh = 0.001f * _state.consumed_mah * _state.voltage; |
|
|
|
// If we got this far then must be healthy |
|
_state.healthy = true; |
|
_state.last_time_micros = AP_HAL::micros(); |
|
} |
|
|
|
AP_BattMonitor::Failsafe AP_BattMonitor_Generator_Elec::update_failsafes() |
|
{ |
|
AP_BattMonitor::Failsafe failsafe = AP_BattMonitor::Failsafe::None; |
|
|
|
AP_Generator *generator = AP::generator(); |
|
|
|
// Only check for failsafes on the electrical moniter |
|
// no point in having the same failsafe on two battery monitors |
|
if (generator != nullptr) { |
|
failsafe = generator->update_failsafes(); |
|
} |
|
return MAX(AP_BattMonitor_Backend::update_failsafes(), failsafe); |
|
} |
|
#endif
|
|
|