#include "AP_BattMonitor_SMBus.h" |
|
|
|
#define AP_BATTMONITOR_SMBUS_PEC_POLYNOME 0x07 // Polynome for CRC generation |
|
|
|
extern const AP_HAL::HAL& hal; |
|
|
|
const AP_Param::GroupInfo AP_BattMonitor_SMBus::var_info[] = { |
|
|
|
// Param indexes must be between 10 and 19 to avoid conflict with other battery monitor param tables loaded by pointer |
|
|
|
// @Param: I2C_BUS |
|
// @DisplayName: Battery monitor I2C bus number |
|
// @Description: Battery monitor I2C bus number |
|
// @Range: 0 3 |
|
// @User: Advanced |
|
// @RebootRequired: True |
|
AP_GROUPINFO("I2C_BUS", 10, AP_BattMonitor_SMBus, _bus, 0), |
|
|
|
// @Param: I2C_ADDR |
|
// @DisplayName: Battery monitor I2C address |
|
// @Description: Battery monitor I2C address |
|
// @Range: 0 127 |
|
// @User: Advanced |
|
// @RebootRequired: True |
|
AP_GROUPINFO("I2C_ADDR", 11, AP_BattMonitor_SMBus, _address, AP_BATTMONITOR_SMBUS_I2C_ADDR), |
|
|
|
// Param indexes must be between 10 and 19 to avoid conflict with other battery monitor param tables loaded by pointer |
|
|
|
AP_GROUPEND |
|
}; |
|
|
|
AP_BattMonitor_SMBus::AP_BattMonitor_SMBus(AP_BattMonitor &mon, |
|
AP_BattMonitor::BattMonitor_State &mon_state, |
|
AP_BattMonitor_Params ¶ms, |
|
uint8_t i2c_bus) |
|
: AP_BattMonitor_Backend(mon, mon_state, params) |
|
{ |
|
AP_Param::setup_object_defaults(this, var_info); |
|
_state.var_info = var_info; |
|
|
|
_bus.set_default(i2c_bus); |
|
_params._serial_number.set(AP_BATT_SERIAL_NUMBER_DEFAULT); |
|
_params._pack_capacity.set(0); |
|
} |
|
|
|
void AP_BattMonitor_SMBus::init(void) |
|
{ |
|
_dev = hal.i2c_mgr->get_device(_bus, _address, 100000, true, 20); |
|
|
|
if (_dev) { |
|
timer_handle = _dev->register_periodic_callback(100000, FUNCTOR_BIND_MEMBER(&AP_BattMonitor_SMBus::timer, void)); |
|
} |
|
} |
|
|
|
// return true if cycle count can be provided and fills in cycles argument |
|
bool AP_BattMonitor_SMBus::get_cycle_count(uint16_t &cycles) const |
|
{ |
|
if (!_has_cycle_count) { |
|
return false; |
|
} |
|
cycles = _cycle_count; |
|
return true; |
|
} |
|
|
|
/// read the battery_voltage and current, should be called at 10hz |
|
void AP_BattMonitor_SMBus::read(void) |
|
{ |
|
// nothing to be done here for actually interacting with the battery |
|
// however we can use this to set any parameters that need to be set |
|
|
|
if (_serial_number != _params._serial_number) { |
|
_params._serial_number.set_and_notify(_serial_number); |
|
} |
|
|
|
if (_full_charge_capacity != _params._pack_capacity) { |
|
_params._pack_capacity.set_and_notify(_full_charge_capacity); |
|
} |
|
} |
|
|
|
// reads the pack full charge capacity |
|
// returns if we already knew the pack capacity |
|
void AP_BattMonitor_SMBus::read_full_charge_capacity(void) |
|
{ |
|
if (_full_charge_capacity != 0) { |
|
return; |
|
} |
|
|
|
if (read_word(BATTMONITOR_SMBUS_FULL_CHARGE_CAPACITY, _full_charge_capacity)) { |
|
_full_charge_capacity *= get_capacity_scaler(); |
|
} |
|
} |
|
|
|
// reads the remaining capacity |
|
// which will only be read if we know the full charge capacity (accounting for battery degradation) |
|
void AP_BattMonitor_SMBus::read_remaining_capacity(void) |
|
{ |
|
int32_t capacity = _params._pack_capacity; |
|
|
|
if (capacity <= 0) { |
|
return; |
|
} |
|
|
|
uint16_t data; |
|
if (read_word(BATTMONITOR_SMBUS_REMAINING_CAPACITY, data)) { |
|
_state.consumed_mah = MAX(0, capacity - (data * get_capacity_scaler())); |
|
} |
|
} |
|
|
|
// reads the temperature word from the battery |
|
void AP_BattMonitor_SMBus::read_temp(void) |
|
{ |
|
uint16_t data; |
|
if (!read_word(BATTMONITOR_SMBUS_TEMP, data)) { |
|
_has_temperature = (AP_HAL::millis() - _state.temperature_time) <= AP_BATT_MONITOR_TIMEOUT; |
|
return; |
|
} |
|
_has_temperature = true; |
|
|
|
_state.temperature_time = AP_HAL::millis(); |
|
_state.temperature = KELVIN_TO_C(0.1f * data); |
|
} |
|
|
|
// reads the serial number if it's not already known |
|
// returns if the serial number was already known |
|
void AP_BattMonitor_SMBus::read_serial_number(void) |
|
{ |
|
// don't recheck the serial number if we already have it |
|
if (_serial_number != -1) { |
|
return; |
|
} |
|
|
|
uint16_t data; |
|
if (read_word(BATTMONITOR_SMBUS_SERIAL, data)) { |
|
_serial_number = data; |
|
} |
|
} |
|
|
|
// reads the battery's cycle count |
|
void AP_BattMonitor_SMBus::read_cycle_count() |
|
{ |
|
// only read cycle count once |
|
if (_has_cycle_count) { |
|
return; |
|
} |
|
_has_cycle_count = read_word(BATTMONITOR_SMBUS_CYCLE_COUNT, _cycle_count); |
|
} |
|
|
|
// read word from register |
|
// returns true if read was successful, false if failed |
|
bool AP_BattMonitor_SMBus::read_word(uint8_t reg, uint16_t& data) const |
|
{ |
|
// buffer to hold results (1 extra byte returned holding PEC) |
|
const uint8_t read_size = 2 + (_pec_supported ? 1 : 0); |
|
uint8_t buff[read_size]; // buffer to hold results |
|
|
|
// read the appropriate register from the device |
|
if (!_dev->read_registers(reg, buff, sizeof(buff))) { |
|
return false; |
|
} |
|
|
|
// check PEC |
|
if (_pec_supported) { |
|
const uint8_t pec = get_PEC(_address, reg, true, buff, 2); |
|
if (pec != buff[2]) { |
|
return false; |
|
} |
|
} |
|
|
|
// convert buffer to word |
|
data = (uint16_t)buff[1]<<8 | (uint16_t)buff[0]; |
|
|
|
// return success |
|
return true; |
|
} |
|
|
|
/// get_PEC - calculate packet error correction code of buffer |
|
uint8_t AP_BattMonitor_SMBus::get_PEC(const uint8_t i2c_addr, uint8_t cmd, bool reading, const uint8_t buff[], uint8_t len) const |
|
{ |
|
// exit immediately if no data |
|
if (len == 0) { |
|
return 0; |
|
} |
|
|
|
// prepare temp buffer for calculating crc |
|
uint8_t tmp_buff[len+3]; |
|
tmp_buff[0] = i2c_addr << 1; |
|
tmp_buff[1] = cmd; |
|
tmp_buff[2] = tmp_buff[0] | (uint8_t)reading; |
|
memcpy(&tmp_buff[3],buff,len); |
|
|
|
// initialise crc to zero |
|
uint8_t crc = 0; |
|
uint8_t shift_reg = 0; |
|
bool do_invert; |
|
|
|
// for each byte in the stream |
|
for (uint8_t i=0; i<sizeof(tmp_buff); i++) { |
|
// load next data byte into the shift register |
|
shift_reg = tmp_buff[i]; |
|
// for each bit in the current byte |
|
for (uint8_t j=0; j<8; j++) { |
|
do_invert = (crc ^ shift_reg) & 0x80; |
|
crc <<= 1; |
|
shift_reg <<= 1; |
|
if(do_invert) { |
|
crc ^= AP_BATTMONITOR_SMBUS_PEC_POLYNOME; |
|
} |
|
} |
|
} |
|
|
|
// return result |
|
return crc; |
|
}
|
|
|