/// -*- tab-width: 4; Mode: C++; c-basic-offset: 4; indent-tabs-mode: nil -*- |
|
|
|
#include <AP_HAL.h> |
|
|
|
#if CONFIG_HAL_BOARD == HAL_BOARD_PX4 |
|
#include <AP_Baro.h> |
|
#include "AP_Baro_PX4.h" |
|
|
|
#include <sys/types.h> |
|
#include <sys/stat.h> |
|
#include <fcntl.h> |
|
#include <unistd.h> |
|
|
|
#include <drivers/drv_baro.h> |
|
#include <uORB/uORB.h> |
|
#include <uORB/topics/sensor_combined.h> |
|
|
|
extern const AP_HAL::HAL& hal; |
|
|
|
// Public Methods ////////////////////////////////////////////////////////////// |
|
bool AP_Baro_PX4::init(void) |
|
{ |
|
if (_baro_fd == -1) { |
|
_baro_fd = open(BARO_DEVICE_PATH, O_RDONLY); |
|
if (_baro_fd < 0) { |
|
hal.scheduler->panic("Unable to open " BARO_DEVICE_PATH); |
|
} |
|
|
|
/* set the driver to poll at 150Hz */ |
|
ioctl(_baro_fd, SENSORIOCSPOLLRATE, 150); |
|
|
|
// average over up to 10 samples |
|
ioctl(_baro_fd, SENSORIOCSQUEUEDEPTH, 10); |
|
} |
|
|
|
return true; |
|
} |
|
|
|
// Read the sensor |
|
uint8_t AP_Baro_PX4::read(void) |
|
{ |
|
uint16_t count; |
|
float pressure_sum, temperature_sum; |
|
struct baro_report baro_report; |
|
|
|
// read all available samples and average |
|
pressure_sum = 0; |
|
temperature_sum = 0; |
|
count = 0; |
|
|
|
while (::read(_baro_fd, &baro_report, sizeof(baro_report)) == sizeof(baro_report)) { |
|
pressure_sum += baro_report.pressure; // Pressure in mbar |
|
temperature_sum += baro_report.temperature; // degrees celcius |
|
count++; |
|
} |
|
|
|
if (count != 0) { |
|
_pressure = pressure_sum / count; |
|
_temperature = temperature_sum / count; |
|
_last_update = hal.scheduler->millis(); |
|
_pressure_samples = count; |
|
healthy = true; |
|
return 1; |
|
} |
|
|
|
return 0; |
|
} |
|
|
|
float AP_Baro_PX4::get_pressure() { |
|
return _pressure; |
|
} |
|
|
|
float AP_Baro_PX4::get_temperature() { |
|
return _temperature; |
|
} |
|
|
|
int32_t AP_Baro_PX4::get_raw_pressure() { |
|
return _pressure; |
|
} |
|
|
|
int32_t AP_Baro_PX4::get_raw_temp() { |
|
return _temperature; |
|
} |
|
|
|
#endif // CONFIG_HAL_BOARD
|
|
|