DPS280 barometer driver |
|
*/ |
|
|
|
#include "AP_Baro_DPS280.h" |
|
|
|
#include <utility> |
|
#include <stdio.h> |
|
|
|
extern const AP_HAL::HAL &hal; |
|
|
|
#define DPS280_REG_PRESS 0x00 |
|
#define DPS280_REG_TEMP 0x03 |
|
#define DPS280_REG_PCONF 0x06 |
|
#define DPS280_REG_TCONF 0x07 |
|
#define DPS280_REG_MCONF 0x08 |
|
#define DPS280_REG_CREG 0x09 |
|
#define DPS280_REG_ISTS 0x0A |
|
#define DPS280_REG_FSTS 0x0B |
|
#define DPS280_REG_RESET 0x0C |
|
#define DPS280_REG_PID 0x0D |
|
#define DPS280_REG_COEF 0x10 |
|
#define DPS280_REG_CSRC 0x28 |
|
|
|
#define DPS280_WHOAMI 0x10 |
|
|
|
#define TEMPERATURE_LIMIT_C 120 |
|
|
|
AP_Baro_DPS280::AP_Baro_DPS280(AP_Baro &baro, AP_HAL::OwnPtr<AP_HAL::Device> _dev) |
|
: AP_Baro_Backend(baro) |
|
, dev(std::move(_dev)) |
|
{ |
|
} |
|
|
|
AP_Baro_Backend *AP_Baro_DPS280::probe(AP_Baro &baro, |
|
AP_HAL::OwnPtr<AP_HAL::Device> _dev, bool _is_dps310) |
|
{ |
|
if (!_dev) { |
|
return nullptr; |
|
} |
|
|
|
AP_Baro_DPS280 *sensor = new AP_Baro_DPS280(baro, std::move(_dev)); |
|
if (sensor) { |
|
sensor->is_dps310 = _is_dps310; |
|
} |
|
if (!sensor || !sensor->init()) { |
|
delete sensor; |
|
return nullptr; |
|
} |
|
return sensor; |
|
} |
|
|
|
AP_Baro_Backend *AP_Baro_DPS310::probe(AP_Baro &baro, |
|
AP_HAL::OwnPtr<AP_HAL::Device> _dev) |
|
{ |
|
// same as DPS280 but with is_dps310 set for temperature fix |
|
return AP_Baro_DPS280::probe(baro, std::move(_dev), true); |
|
} |
|
|
|
/* |
|
handle bit width for 16 bit config registers |
|
*/ |
|
void AP_Baro_DPS280::fix_config_bits16(int16_t &v, uint8_t bits) const |
|
{ |
|
if (v > int16_t((1U<<(bits-1))-1)) { |
|
v = v - (1U<<bits); |
|
} |
|
} |
|
|
|
/* |
|
handle bit width for 32 bit config registers |
|
*/ |
|
void AP_Baro_DPS280::fix_config_bits32(int32_t &v, uint8_t bits) const |
|
{ |
|
if (v > int32_t((1U<<(bits-1))-1)) { |
|
v = v - (1U<<bits); |
|
} |
|
} |
|
|
|
/* |
|
read calibration data |
|
*/ |
|
bool AP_Baro_DPS280::read_calibration(void) |
|
{ |
|
uint8_t buf[18]; |
|
|
|
if (!dev->read_registers(DPS280_REG_COEF, buf, 18)) { |
|
return false; |
|
} |
|
|
|
calibration.C0 = (buf[0] << 4) + ((buf[1] >>4) & 0x0F); |
|
calibration.C1 = (buf[2] + ((buf[1] & 0x0F)<<8)); |
|
calibration.C00 = ((buf[4]<<4) + (buf[3]<<12)) + ((buf[5]>>4) & 0x0F); |
|
calibration.C10 = ((buf[5] & 0x0F)<<16) + buf[7] + (buf[6]<<8); |
|
calibration.C01 = (buf[9] + (buf[8]<<8)); |
|
calibration.C11 = (buf[11] + (buf[10]<<8)); |
|
calibration.C20 = (buf[13] + (buf[12]<<8)); |
|
calibration.C21 = (buf[15] + (buf[14]<<8)); |
|
calibration.C30 = (buf[17] + (buf[16]<<8)); |
|
|
|
fix_config_bits16(calibration.C0, 12); |
|
fix_config_bits16(calibration.C1, 12); |
|
fix_config_bits32(calibration.C00, 20); |
|
fix_config_bits32(calibration.C10, 20); |
|
fix_config_bits16(calibration.C01, 16); |
|
fix_config_bits16(calibration.C11, 16); |
|
fix_config_bits16(calibration.C20, 16); |
|
fix_config_bits16(calibration.C21, 16); |
|
fix_config_bits16(calibration.C30, 16); |
|
|
|
/* get calibration source */ |
|
if (!dev->read_registers(DPS280_REG_CSRC, &calibration.temp_source, 1)) { |
|
return false; |
|
} |
|
calibration.temp_source &= 0x80; |
|
|
|
return true; |
|
} |
|
|
|
void AP_Baro_DPS280::set_config_registers(void) |
|
{ |
|
dev->write_register(DPS280_REG_CREG, 0x0C, true); // shift for 16x oversampling |
|
dev->write_register(DPS280_REG_PCONF, 0x54, true); // 32 Hz, 16x oversample |
|
dev->write_register(DPS280_REG_TCONF, 0x54 | calibration.temp_source, true); // 32 Hz, 16x oversample |
|
dev->write_register(DPS280_REG_MCONF, 0x07); // continuous temp and pressure. |
|
|
|
if (is_dps310) { |
|
// work around broken temperature handling on some sensors |
|
// using undocumented register writes |
|
// see https://github.com/infineon/DPS310-Pressure-Sensor/blob/dps310/src/DpsClass.cpp#L442 |
|
dev->write_register(0x0E, 0xA5); |
|
dev->write_register(0x0F, 0x96); |
|
dev->write_register(0x62, 0x02); |
|
dev->write_register(0x0E, 0x00); |
|
dev->write_register(0x0F, 0x00); |
|
} |
|
} |
|
|
|
bool AP_Baro_DPS280::init() |
|
{ |
|
if (!dev) { |
|
return false; |
|
} |
|
dev->get_semaphore()->take_blocking(); |
|
|
|
// setup to allow reads on SPI |
|
if (dev->bus_type() == AP_HAL::Device::BUS_TYPE_SPI) { |
|
dev->set_read_flag(0x80); |
|
} |
|
|
|
dev->set_speed(AP_HAL::Device::SPEED_HIGH); |
|
|
|
// the DPS310 can get into a state on boot where the whoami is not |
|
// read correctly at startup. Toggling the CS line gets its out of |
|
// this state |
|
dev->set_chip_select(true); |
|
dev->set_chip_select(false); |
|
|
|
uint8_t whoami=0; |
|
if (!dev->read_registers(DPS280_REG_PID, &whoami, 1) || |
|
whoami != DPS280_WHOAMI) { |
|
dev->get_semaphore()->give(); |
|
return false; |
|
} |
|
|
|
if (!read_calibration()) { |
|
dev->get_semaphore()->give(); |
|
return false; |
|
} |
|
|
|
dev->setup_checked_registers(4, 20); |
|
|
|
set_config_registers(); |
|
|
|
instance = _frontend.register_sensor(); |
|
|
|
dev->set_device_type(DEVTYPE_BARO_DPS280); |
|
set_bus_id(instance, dev->get_bus_id()); |
|
|
|
dev->get_semaphore()->give(); |
|
|
|
// request 64Hz update. New data will be available at 32Hz |
|
dev->register_periodic_callback((1000 / 64) * AP_USEC_PER_MSEC, FUNCTOR_BIND_MEMBER(&AP_Baro_DPS280::timer, void)); |
|
|
|
return true; |
|
} |
|
|
|
/* |
|
calculate corrected pressure and temperature |
|
*/ |
|
void AP_Baro_DPS280::calculate_PT(int32_t UT, int32_t UP, float &pressure, float &temperature) |
|
{ |
|
const struct dps280_cal &cal = calibration; |
|
// scaling for 16x oversampling |
|
const float scaling_16 = 1.0f/253952; |
|
|
|
float temp_scaled; |
|
float press_scaled; |
|
|
|
temp_scaled = float(UT) * scaling_16; |
|
temperature = cal.C0 * 0.5f + cal.C1 * temp_scaled; |
|
|
|
press_scaled = float(UP) * scaling_16; |
|
|
|
pressure = cal.C00; |
|
pressure += press_scaled * (cal.C10 + press_scaled * (cal.C20 + press_scaled * cal.C30)); |
|
pressure += temp_scaled * cal.C01; |
|
pressure += temp_scaled * press_scaled * (cal.C11 + press_scaled * cal.C21); |
|
} |
|
|
|
/* |
|
check health and possibly reset |
|
*/ |
|
void AP_Baro_DPS280::check_health(void) |
|
{ |
|
dev->check_next_register(); |
|
|
|
if (fabsf(last_temperature) > TEMPERATURE_LIMIT_C) { |
|
err_count++; |
|
} |
|
if (err_count > 16) { |
|
err_count = 0; |
|
dev->write_register(DPS280_REG_RESET, 0x09); |
|
set_config_registers(); |
|
pending_reset = true; |
|
} |
|
} |
|
|
|
// acumulate a new sensor reading |
|
void AP_Baro_DPS280::timer(void) |
|
{ |
|
uint8_t buf[6]; |
|
uint8_t ready; |
|
|
|
if (pending_reset) { |
|
// reset registers after software reset from check_health() |
|
pending_reset = false; |
|
set_config_registers(); |
|
return; |
|
} |
|
|
|
if (!dev->read_registers(DPS280_REG_MCONF, &ready, 1) || |
|
!(ready & (1U<<4)) || |
|
!dev->read_registers(DPS280_REG_PRESS, buf, 3) || |
|
!dev->read_registers(DPS280_REG_TEMP, &buf[3], 3)) { |
|
// data not ready |
|
err_count++; |
|
check_health(); |
|
return; |
|
} |
|
|
|
int32_t press = (buf[2]) + (buf[1]<<8) + (buf[0]<<16); |
|
int32_t temp = (buf[5]) + (buf[4]<<8) + (buf[3]<<16); |
|
fix_config_bits32(press, 24); |
|
fix_config_bits32(temp, 24); |
|
|
|
float pressure, temperature; |
|
|
|
calculate_PT(temp, press, pressure, temperature); |
|
|
|
last_temperature = temperature; |
|
|
|
if (!pressure_ok(pressure)) { |
|
return; |
|
} |
|
|
|
check_health(); |
|
|
|
if (fabsf(last_temperature) <= TEMPERATURE_LIMIT_C) { |
|
err_count = 0; |
|
} |
|
|
|
WITH_SEMAPHORE(_sem); |
|
|
|
pressure_sum += pressure; |
|
temperature_sum += temperature; |
|
count++; |
|
} |
|
|
|
// transfer data to the frontend |
|
void AP_Baro_DPS280::update(void) |
|
{ |
|
if (count == 0) { |
|
return; |
|
} |
|
|
|
WITH_SEMAPHORE(_sem); |
|
|
|
_copy_to_frontend(instance, pressure_sum/count, temperature_sum/count); |
|
pressure_sum = 0; |
|
temperature_sum = 0; |
|
count=0; |
|
}
|
|
|