Reset MS5611 baro sensor after an error

Reset MS5611 baro sensor after an error in order to avoid endless error
loops
sbg
Kynos 11 years ago
parent
commit
2de01964e2
  1. 5
      src/drivers/ms5611/ms5611.cpp

5
src/drivers/ms5611/ms5611.cpp

@ -526,6 +526,7 @@ void @@ -526,6 +526,7 @@ void
MS5611::cycle()
{
int ret;
unsigned dummy;
/* collection phase? */
if (_collect_phase) {
@ -542,6 +543,8 @@ MS5611::cycle() @@ -542,6 +543,8 @@ MS5611::cycle()
} else {
//log("collection error %d", ret);
}
/* issue a reset command to the sensor */
_interface->ioctl(IOCTL_RESET, dummy);
/* reset the collection state machine and try again */
start_cycle();
return;
@ -573,6 +576,8 @@ MS5611::cycle() @@ -573,6 +576,8 @@ MS5611::cycle()
ret = measure();
if (ret != OK) {
//log("measure error %d", ret);
/* issue a reset command to the sensor */
_interface->ioctl(IOCTL_RESET, dummy);
/* reset the collection state machine and try again */
start_cycle();
return;

Loading…