Browse Source

Commander: call battery_status_check on update instead of early return

master
Matthias Grob 4 years ago
parent
commit
5489005e0b
  1. 11
      src/modules/commander/Commander.cpp

11
src/modules/commander/Commander.cpp

@ -2190,7 +2190,9 @@ Commander::run() @@ -2190,7 +2190,9 @@ Commander::run()
_cpuload_sub.update(&_cpuload);
battery_status_check();
if (_battery_status_subs.updated()) {
battery_status_check();
}
/* If in INIT state, try to proceed to STANDBY state */
if (!_status_flags.condition_calibration_enabled && _status.arming_state == vehicle_status_s::ARMING_STATE_INIT) {
@ -3604,13 +3606,6 @@ void Commander::avoidance_check() @@ -3604,13 +3606,6 @@ void Commander::avoidance_check()
void Commander::battery_status_check()
{
// We need to update the status flag if ANY battery is updated, because the system source might have
// changed, or might be nothing (if there is no battery connected)
if (!_battery_status_subs.updated()) {
// Nothing has changed since the last time this function was called, so nothing needs to be done now.
return;
}
battery_status_s batteries[_battery_status_subs.size()];
size_t num_connected_batteries = 0;

Loading…