@ -85,7 +85,7 @@ public:
@@ -85,7 +85,7 @@ public:
|
|
|
|
|
R_LOS = 0.03f; // optical flow measurement noise variance (rad/sec)^2
|
|
|
|
|
flowInnovGate = 3.0f; // number of standard deviations applied to the optical flow innovation consistency check
|
|
|
|
|
auxFlowInnovGate = 10.0f; // number of standard deviations applied to the optical flow innovation consistency check used by the auxiliary filter
|
|
|
|
|
rngInnovGate = 5.0f; // number of standard deviations applied to the rnage finder innovation consistency check
|
|
|
|
|
rngInnovGate = 10.0f; // number of standard deviations applied to the rnage finder innovation consistency check
|
|
|
|
|
minFlowRng = 0.01f; //minimum range between ground and flow sensor
|
|
|
|
|
moCompR_LOS = 0.2; // scaler from sensor gyro rate to uncertainty in LOS rate
|
|
|
|
|
} |
|
|
|
|