@ -143,22 +143,18 @@ void BATT_SMBUS::RunImpl()
@@ -143,22 +143,18 @@ void BATT_SMBUS::RunImpl()
|
|
|
|
|
// Check if max lifetime voltage delta is greater than allowed.
|
|
|
|
|
if (_lifetime_max_delta_cell_voltage > BATT_CELL_VOLTAGE_THRESHOLD_FAILED) { |
|
|
|
|
new_report.warning = battery_status_s::BATTERY_WARNING_CRITICAL; |
|
|
|
|
} |
|
|
|
|
|
|
|
|
|
// Propagate warning state.
|
|
|
|
|
else { |
|
|
|
|
if (new_report.remaining > _low_thr) { |
|
|
|
|
new_report.warning = battery_status_s::BATTERY_WARNING_NONE; |
|
|
|
|
} else if (new_report.remaining > _low_thr) { |
|
|
|
|
new_report.warning = battery_status_s::BATTERY_WARNING_NONE; |
|
|
|
|
|
|
|
|
|
} else if (new_report.remaining > _crit_thr) { |
|
|
|
|
new_report.warning = battery_status_s::BATTERY_WARNING_LOW; |
|
|
|
|
} else if (new_report.remaining > _crit_thr) { |
|
|
|
|
new_report.warning = battery_status_s::BATTERY_WARNING_LOW; |
|
|
|
|
|
|
|
|
|
} else if (new_report.remaining > _emergency_thr) { |
|
|
|
|
new_report.warning = battery_status_s::BATTERY_WARNING_CRITICAL; |
|
|
|
|
} else if (new_report.remaining > _emergency_thr) { |
|
|
|
|
new_report.warning = battery_status_s::BATTERY_WARNING_CRITICAL; |
|
|
|
|
|
|
|
|
|
} else { |
|
|
|
|
new_report.warning = battery_status_s::BATTERY_WARNING_EMERGENCY; |
|
|
|
|
} |
|
|
|
|
} else { |
|
|
|
|
new_report.warning = battery_status_s::BATTERY_WARNING_EMERGENCY; |
|
|
|
|
} |
|
|
|
|
|
|
|
|
|
// Read battery temperature and covert to Celsius.
|
|
|
|
@ -168,6 +164,7 @@ void BATT_SMBUS::RunImpl()
@@ -168,6 +164,7 @@ void BATT_SMBUS::RunImpl()
|
|
|
|
|
new_report.capacity = _batt_capacity; |
|
|
|
|
new_report.cycle_count = _cycle_count; |
|
|
|
|
new_report.serial_number = _serial_number; |
|
|
|
|
new_report.max_cell_voltage_delta = _max_cell_voltage_delta; |
|
|
|
|
new_report.cell_count = _cell_count; |
|
|
|
|
new_report.voltage_cell_v[0] = _cell_voltages[0]; |
|
|
|
|
new_report.voltage_cell_v[1] = _cell_voltages[1]; |
|
|
|
@ -219,7 +216,7 @@ int BATT_SMBUS::get_cell_voltages()
@@ -219,7 +216,7 @@ int BATT_SMBUS::get_cell_voltages()
|
|
|
|
|
|
|
|
|
|
for (uint8_t i = 1; i < (sizeof(_cell_voltages) / sizeof(_cell_voltages[0])); i++) { |
|
|
|
|
_min_cell_voltage = math::min(_min_cell_voltage, _cell_voltages[i]); |
|
|
|
|
max_cell_voltage = math::max(_min_cell_voltage, _cell_voltages[i]); |
|
|
|
|
max_cell_voltage = math::max(max_cell_voltage, _cell_voltages[i]); |
|
|
|
|
} |
|
|
|
|
|
|
|
|
|
// Calculate the max difference between the min and max cells with complementary filter.
|
|
|
|
|