When performing the initial in-flight magnetic field reset for fixed wing vehicles, resetting the quaternion states and their corresponding covariances should be avoided unless yaw errors are large, because state estimates are vulnerable to transient sensor errors immediately following a reset.master
Paul Riseborough
7 years ago
1 changed files with 16 additions and 2 deletions