Browse Source

EKF: don't reset quaternions unnecessarily

When performing the initial in-flight magnetic field reset for fixed wing vehicles, resetting the quaternion states and their corresponding covariances should be avoided unless yaw errors are large, because state estimates are vulnerable to transient sensor errors immediately following a reset.
master
Paul Riseborough 7 years ago
parent
commit
9e47b6e1b6
  1. 18
      EKF/ekf_helper.cpp

18
EKF/ekf_helper.cpp

@ -461,9 +461,23 @@ bool Ekf::realignYawGPS() @@ -461,9 +461,23 @@ bool Ekf::realignYawGPS()
return true;
} else {
// attempt a normal alignment using the magnetometer
return resetMagHeading(_mag_sample_delayed.mag);
// align mag states only
// calculate initial earth magnetic field states
_state.mag_I = _R_to_earth * _mag_sample_delayed.mag;
// reset the corresponding rows and columns in the covariance matrix and set the variances on the magnetic field states to the measurement variance
zeroRows(P, 16, 21);
zeroCols(P, 16, 21);
for (uint8_t index = 16; index <= 21; index ++) {
P[index][index] = sq(_params.mag_noise);
}
// record the start time for the magnetic field alignment
_flt_mag_align_start_time = _imu_sample_delayed.time_us;
return true;
}
} else {

Loading…
Cancel