- extract motion checks performed on ground
- move all non-timing check to controlOpticalFlowFusion. This simplifies and standardirzes the setOpticalFlowData function. Furthermore, in some cases (SITL, PX4Flow), the dt is forced to 0 when the quality is 0 (which is usual on ground) so the ekf needs to ignore those values on ground to initialize properly the flow fusion.
- add filter convergence test
- move check for dt time max in setOpticalFlowData
- in the simulator, do not update dt as this is the sensor integration
period.
* EKF: Add comparison test for mag field fusion generated code
* EKF: convert mag field fusion to use SymPy generated code
* EKF: Add test comparison program for yaw fusion equations
* Stop setting 0 to 0
* Reduce if/else statement to only if
* EKF: more accurate implementation for sequential fusion of magnetometer data
* test: update change indicator
* Use matrix::SparseVector<float, 24, ...> for observation jacobian
* Adapt the auto code generation to allow for different bracket styles
* Add auto generated code for mag fusion
* Add generic computation of KHP
* Apply generic computation of KHP to mag fusion
* tests: update change indicator
* tests: update change indicator
Co-authored-by: kamilritz <kritz@ethz.ch>
If the user selects GPS yaw fusion but that there is no GPS yaw data in
the GPS message or if the fusion is rejected for some time, the GPS yaw
data is declared faulty and the fusion is stopped to allow an other
source of yaw aiding to start.
- do not gps reference altitude to zero in case gps checks pass before the
filter initialized
- reset the filtered gps position and position derivative filters in case
we are in air or there is movement on the ground
Signed-off-by: RomanBapst <bapstroman@gmail.com>
This is a non-functional change required to select accel bias estimation
per axis selection. The intent is then to disable the learning before
takeoff of the components that are poorly observable.
* Support vision velocity expressed in body frame
* Use switch statement for vision velocity frame
* Robustify vision velocity frame test
* Increase lower bound on vision velocity noise to 0.05 m/s