uint64 timestamp # time since system start (microseconds) |
|
bool connected # Whether or not a battery is connected, based on a voltage threshold |
|
float32 voltage_v # Battery voltage in volts, 0 if unknown |
|
float32 voltage_filtered_v # Battery voltage in volts, filtered, 0 if unknown |
|
float32 current_a # Battery current in amperes, -1 if unknown |
|
float32 current_filtered_a # Battery current in amperes, filtered, 0 if unknown |
|
float32 current_average_a # Battery current average in amperes, -1 if unknown |
|
float32 discharged_mah # Discharged amount in mAh, -1 if unknown |
|
float32 remaining # From 1 to 0, -1 if unknown |
|
float32 scale # Power scaling factor, >= 1, or -1 if unknown |
|
float32 time_remaining_s # predicted time in seconds remaining until battery is empty under previous averaged load, NAN if unknown |
|
float32 temperature # temperature of the battery. NaN if unknown |
|
uint8 cell_count # Number of cells, 0 if unknown |
|
|
|
uint8 BATTERY_SOURCE_POWER_MODULE = 0 |
|
uint8 BATTERY_SOURCE_EXTERNAL = 1 |
|
uint8 BATTERY_SOURCE_ESCS = 2 |
|
uint8 source # Battery source |
|
uint8 priority # Zero based priority is the connection on the Power Controller V1..Vn AKA BrickN-1 |
|
uint16 capacity # actual capacity of the battery |
|
uint16 cycle_count # number of discharge cycles the battery has experienced |
|
uint16 average_time_to_empty # predicted remaining battery capacity based on the average rate of discharge in min |
|
uint16 serial_number # serial number of the battery pack |
|
uint16 manufacture_date # manufacture date, part of serial number of the battery pack. Formatted as: Day + Month×32 + (Year–1980)×512 |
|
uint16 state_of_health # state of health. FullChargeCapacity/DesignCapacity, 0-100%. |
|
uint16 max_error # max error, expected margin of error in % in the state-of-charge calculation with a range of 1 to 100% |
|
uint8 id # ID number of a battery. Should be unique and consistent for the lifetime of a vehicle. 1-indexed. |
|
uint16 interface_error # interface error counter |
|
|
|
float32[14] voltage_cell_v # Battery individual cell voltages, 0 if unknown |
|
float32 max_cell_voltage_delta # Max difference between individual cell voltages |
|
|
|
bool is_powering_off # Power off event imminent indication, false if unknown |
|
bool is_required # Set if the battery is explicitly required before arming |
|
|
|
|
|
uint8 BATTERY_WARNING_NONE = 0 # no battery low voltage warning active |
|
uint8 BATTERY_WARNING_LOW = 1 # warning of low voltage |
|
uint8 BATTERY_WARNING_CRITICAL = 2 # critical voltage, return / abort immediately |
|
uint8 BATTERY_WARNING_EMERGENCY = 3 # immediate landing required |
|
uint8 BATTERY_WARNING_FAILED = 4 # the battery has failed completely |
|
uint8 BATTERY_STATE_UNHEALTHY = 6 # Battery is diagnosed to be defective or an error occurred, usage is discouraged / prohibited. Possible causes (faults) are listed in faults field. |
|
uint8 BATTERY_STATE_CHARGING = 7 # Battery is charging |
|
|
|
uint8 BATTERY_FAULT_DEEP_DISCHARGE = 0 # Battery has deep discharged |
|
uint8 BATTERY_FAULT_SPIKES = 1 # Voltage spikes |
|
uint8 BATTERY_FAULT_CELL_FAIL= 2 # One or more cells have failed |
|
uint8 BATTERY_FAULT_OVER_CURRENT = 3 # Over-current |
|
uint8 BATTERY_FAULT_OVER_TEMPERATURE = 4 # Over-temperature |
|
uint8 BATTERY_FAULT_UNDER_TEMPERATURE = 5 # Under-temperature fault |
|
uint8 BATTERY_FAULT_INCOMPATIBLE_VOLTAGE = 6 # Vehicle voltage is not compatible with battery one |
|
uint8 BATTERY_FAULT_INCOMPATIBLE_FIRMWARE = 7 # Battery firmware is not compatible with current autopilot firmware |
|
uint8 BATTERY_FAULT_INCOMPATIBLE_MODEL = 8 # Battery model is not supported by the system |
|
uint8 BATTERY_FAULT_HARDWARE_FAILURE = 9 # hardware problem |
|
uint8 BATTERY_WARNING_OVER_TEMPERATURE = 10 # Over-temperature |
|
uint8 BATTERY_FAULT_COUNT = 11 # Counter - keep it as last element! |
|
|
|
uint16 faults # Smart battery supply status/fault flags (bitmask) for health indication. |
|
uint32 custom_faults # Bitmask indicating smart battery internal manufacturer faults, those are not user actionable. |
|
uint8 warning # Current battery warning |
|
uint8 mode # Battery mode. Note, the normal operation mode |
|
|
|
uint8 BATTERY_MODE_UNKNOWN = 0 # Battery does not support a mode, or if it does, is operational |
|
uint8 BATTERY_MODE_AUTO_DISCHARGING = 1 # Battery is auto discharging (towards storage level) |
|
uint8 BATTERY_MODE_HOT_SWAP = 2 # Battery in hot-swap mode |
|
uint8 BATTERY_MODE_COUNT = 3 # Counter - keep it as last element (once we're fully migrated to events interface we can just comment this)! |
|
|
|
|
|
uint8 MAX_INSTANCES = 4 |
|
|
|
float32 average_power # The average power of the current discharge |
|
float32 available_energy # The predicted charge or energy remaining in the battery |
|
float32 full_charge_capacity_wh # The compensated battery capacity |
|
float32 remaining_capacity_wh # The compensated battery capacity remaining |
|
float32 design_capacity # The design capacity of the battery |
|
uint16 average_time_to_full # The predicted remaining time until the battery reaches full charge, in minutes |
|
uint16 over_discharge_count # Number of battery overdischarge |
|
float32 nominal_voltage # Nominal voltage of the battery pack
|
|
|