uint64 timestamp # time since system start (microseconds) |
|
float32 voltage_v # Battery voltage in volts, 0 if unknown |
|
float32 voltage_filtered_v # Battery voltage in volts, filtered, 0 if unknown |
|
float32 current_a # Battery current in amperes, -1 if unknown |
|
float32 current_filtered_a # Battery current in amperes, filtered, 0 if unknown |
|
float32 average_current_a # Battery current average in amperes, -1 if unknown |
|
float32 discharged_mah # Discharged amount in mAh, -1 if unknown |
|
float32 remaining # From 1 to 0, -1 if unknown |
|
float32 scale # Power scaling factor, >= 1, or -1 if unknown |
|
float32 temperature # temperature of the battery. NaN if unknown |
|
int32 cell_count # Number of cells |
|
bool connected # Whether or not a battery is connected, based on a voltage threshold |
|
|
|
uint8 BATTERY_SOURCE_POWER_MODULE = 0 |
|
uint8 BATTERY_SOURCE_EXTERNAL = 1 |
|
uint8 BATTERY_SOURCE_ESCS = 2 |
|
uint8 source # Battery source |
|
uint8 priority # Zero based priority is the connection on the Power Controller V1..Vn AKA BrickN-1 |
|
uint16 capacity # actual capacity of the battery |
|
uint16 cycle_count # number of discharge cycles the battery has experienced |
|
uint16 run_time_to_empty # predicted remaining battery capacity based on the present rate of discharge in min |
|
uint16 average_time_to_empty # predicted remaining battery capacity based on the average rate of discharge in min |
|
uint16 serial_number # serial number of the battery pack |
|
uint16 state_of_health # state of health. FullChargeCapacity/DesignCapacity. |
|
uint16 max_error # max error, expected margin of error in % in the state-of-charge calculation with a range of 1 to 100% |
|
uint8 id # ID number of a battery. Should be unique and consistent for the lifetime of a vehicle. 1-indexed. |
|
|
|
float32[10] voltage_cell_v # Battery individual cell voltages |
|
float32 max_cell_voltage_delta # Max difference between individual cell voltages |
|
|
|
bool is_powering_off # Power off event imminent indication, false if unknown |
|
|
|
|
|
uint8 BATTERY_WARNING_NONE = 0 # no battery low voltage warning active |
|
uint8 BATTERY_WARNING_LOW = 1 # warning of low voltage |
|
uint8 BATTERY_WARNING_CRITICAL = 2 # critical voltage, return / abort immediately |
|
uint8 BATTERY_WARNING_EMERGENCY = 3 # immediate landing required |
|
uint8 BATTERY_WARNING_FAILED = 4 # the battery has failed completely |
|
|
|
uint8 warning # current battery warning
|
|
|