// @Description: This limits the number of centi-degrees of elevator over which the integrator will operate. At the default setting of 1500 centi-degrees, the integrator will be limited to +- 15 degrees of servo travel. The maximum servo deflection is +- 45 degrees, so the default value represents a 1/3rd of the total control throw which is adequate for most aircraft unless they are severely out of trim or have very limited elevator control effectiveness.
// @Description: This limits the number of degrees of aileron in centi-dgrees over which the integrator will operate. At the default setting of 1500 centi-degrees, the integrator will be limited to +- 15 degrees of servo travel. The maximum servo deflection is +- 45 centi-degrees, so the default value represents a 1/3rd of the total control throw which is adequate unless the aircraft is severely out of trim.
// @Description: This limits the number of degrees of rudder over which the integrator will operate. At the default setting of 15 degrees, the integrator will be limited to +- 15 degrees of servo travel. The maximum servo deflection is +- 45 degrees, so the default value represents a 1/3rd of the total control throw which is adequate for most aircraft unless they are severely out of trim or have very limited rudder control effectiveness.