Browse Source
this should reduce the chance of baro oscillation due to rapid change in heater temperaturemaster
Andrew Tridgell
5 years ago
2 changed files with 26 additions and 0 deletions
@ -0,0 +1,15 @@
@@ -0,0 +1,15 @@
|
||||
# setup correct defaults for battery monitoring for cube power brick |
||||
BATT2_CURR_PIN 14 |
||||
BATT2_VOLT_PIN 13 |
||||
BATT_AMP_PERVLT 39.877 |
||||
BATT_VOLT_MULT 12.02 |
||||
BATT2_AMP_PERVLT 39.877 |
||||
BATT2_VOLT_MULT 12.02 |
||||
# setup ADSB |
||||
ADSB_ENABLE 1 |
||||
SERIAL5_BAUD 57 |
||||
SERIAL5_PROTOCOL 1 |
||||
|
||||
# lower heater gains |
||||
BRD_IMUHEAT_I 0.07 |
||||
BRD_IMUHEAT_P 50 |
@ -0,0 +1,11 @@
@@ -0,0 +1,11 @@
|
||||
# setup correct defaults for battery monitoring for cube power brick |
||||
BATT2_CURR_PIN 14 |
||||
BATT2_VOLT_PIN 13 |
||||
BATT_AMP_PERVLT 39.877 |
||||
BATT_VOLT_MULT 12.02 |
||||
BATT2_AMP_PERVLT 39.877 |
||||
BATT2_VOLT_MULT 12.02 |
||||
|
||||
# lower heater gains |
||||
BRD_IMUHEAT_I 0.07 |
||||
BRD_IMUHEAT_P 50 |
Loading…
Reference in new issue