if (adc_val == 0) {
if (adc_val == 0 || adc_val == 0xFFFFFF) {
// a failed read can mean the next returned value will be
// corrupt, we must discard it
// corrupt, we must discard it. This copes with MISO being
// pulled either high or low
_discard_next = true;