#pragma once |
|
|
|
#include <AP_Common/AP_Common.h> |
|
#include <AP_Param/AP_Param.h> |
|
#include <AP_Math/AP_Math.h> |
|
#include <GCS_MAVLink/GCS_MAVLink.h> |
|
#include "AP_BattMonitor_Params.h" |
|
|
|
// maximum number of battery monitors |
|
#define AP_BATT_MONITOR_MAX_INSTANCES 9 |
|
|
|
// first monitor is always the primary monitor |
|
#define AP_BATT_PRIMARY_INSTANCE 0 |
|
|
|
#define AP_BATT_SERIAL_NUMBER_DEFAULT -1 |
|
|
|
#define AP_BATT_MONITOR_TIMEOUT 5000 |
|
|
|
#define AP_BATT_MONITOR_RES_EST_TC_1 0.5f |
|
#define AP_BATT_MONITOR_RES_EST_TC_2 0.1f |
|
|
|
// declare backend class |
|
class AP_BattMonitor_Backend; |
|
class AP_BattMonitor_Analog; |
|
class AP_BattMonitor_SMBus; |
|
class AP_BattMonitor_SMBus_Solo; |
|
class AP_BattMonitor_SMBus_Maxell; |
|
class AP_BattMonitor_UAVCAN; |
|
|
|
class AP_BattMonitor |
|
{ |
|
friend class AP_BattMonitor_Backend; |
|
friend class AP_BattMonitor_Analog; |
|
friend class AP_BattMonitor_SMBus; |
|
friend class AP_BattMonitor_SMBus_Solo; |
|
friend class AP_BattMonitor_SMBus_Maxell; |
|
friend class AP_BattMonitor_UAVCAN; |
|
friend class AP_BattMonitor_Sum; |
|
friend class AP_BattMonitor_FuelFlow; |
|
friend class AP_BattMonitor_FuelLevel_PWM; |
|
friend class AP_BattMonitor_Serial_BattGo; |
|
public: |
|
|
|
// battery failsafes must be defined in levels of severity so that vehicles wont fall backwards |
|
enum BatteryFailsafe { |
|
BatteryFailsafe_None = 0, |
|
BatteryFailsafe_Low, |
|
BatteryFailsafe_Critical |
|
}; |
|
|
|
FUNCTOR_TYPEDEF(battery_failsafe_handler_fn_t, void, const char *, const int8_t); |
|
|
|
AP_BattMonitor(uint32_t log_battery_bit, battery_failsafe_handler_fn_t battery_failsafe_handler_fn, const int8_t *failsafe_priorities); |
|
|
|
/* Do not allow copies */ |
|
AP_BattMonitor(const AP_BattMonitor &other) = delete; |
|
AP_BattMonitor &operator=(const AP_BattMonitor&) = delete; |
|
|
|
static AP_BattMonitor *get_singleton() { |
|
return _singleton; |
|
} |
|
|
|
struct cells { |
|
uint16_t cells[MAVLINK_MSG_BATTERY_STATUS_FIELD_VOLTAGES_LEN]; |
|
}; |
|
|
|
// The BattMonitor_State structure is filled in by the backend driver |
|
struct BattMonitor_State { |
|
cells cell_voltages; // battery cell voltages in millivolts, 10 cells matches the MAVLink spec |
|
float voltage; // voltage in volts |
|
float current_amps; // current in amperes |
|
float consumed_mah; // total current draw in milliamp hours since start-up |
|
float consumed_wh; // total energy consumed in Wh since start-up |
|
uint32_t last_time_micros; // time when voltage and current was last read in microseconds |
|
uint32_t low_voltage_start_ms; // time when voltage dropped below the minimum in milliseconds |
|
uint32_t critical_voltage_start_ms; // critical voltage failsafe start timer in milliseconds |
|
float temperature; // battery temperature in degrees Celsius |
|
uint32_t temperature_time; // timestamp of the last received temperature message |
|
float voltage_resting_estimate; // voltage with sag removed based on current and resistance estimate in Volt |
|
float resistance; // resistance, in Ohms, calculated by comparing resting voltage vs in flight voltage |
|
BatteryFailsafe failsafe; // stage failsafe the battery is in |
|
bool healthy; // battery monitor is communicating correctly |
|
bool is_powering_off; // true when power button commands power off |
|
bool powerOffNotified; // only send powering off notification once |
|
}; |
|
|
|
// Return the number of battery monitor instances |
|
uint8_t num_instances(void) const { return _num_instances; } |
|
|
|
// detect and initialise any available battery monitors |
|
void init(); |
|
|
|
/// Read the battery voltage and current for all batteries. Should be called at 10hz |
|
void read(); |
|
|
|
// healthy - returns true if monitor is functioning |
|
bool healthy(uint8_t instance) const; |
|
bool healthy() const { return healthy(AP_BATT_PRIMARY_INSTANCE); } |
|
|
|
/// voltage - returns battery voltage in millivolts |
|
float voltage(uint8_t instance) const; |
|
float voltage() const { return voltage(AP_BATT_PRIMARY_INSTANCE); } |
|
|
|
/// get voltage with sag removed (based on battery current draw and resistance) |
|
/// this will always be greater than or equal to the raw voltage |
|
float voltage_resting_estimate(uint8_t instance) const; |
|
float voltage_resting_estimate() const { return voltage_resting_estimate(AP_BATT_PRIMARY_INSTANCE); } |
|
|
|
/// current_amps - returns the instantaneous current draw in amperes |
|
bool current_amps(float ¤t, const uint8_t instance = AP_BATT_PRIMARY_INSTANCE) const WARN_IF_UNUSED; |
|
|
|
/// consumed_mah - returns total current drawn since start-up in milliampere.hours |
|
bool consumed_mah(float &mah, const uint8_t instance = AP_BATT_PRIMARY_INSTANCE) const WARN_IF_UNUSED; |
|
|
|
/// consumed_wh - returns total energy drawn since start-up in watt.hours |
|
bool consumed_wh(float&wh, const uint8_t instance = AP_BATT_PRIMARY_INSTANCE) const WARN_IF_UNUSED; |
|
|
|
/// capacity_remaining_pct - returns the % battery capacity remaining (0 ~ 100) |
|
virtual uint8_t capacity_remaining_pct(uint8_t instance) const; |
|
uint8_t capacity_remaining_pct() const { return capacity_remaining_pct(AP_BATT_PRIMARY_INSTANCE); } |
|
|
|
/// pack_capacity_mah - returns the capacity of the battery pack in mAh when the pack is full |
|
int32_t pack_capacity_mah(uint8_t instance) const; |
|
int32_t pack_capacity_mah() const { return pack_capacity_mah(AP_BATT_PRIMARY_INSTANCE); } |
|
|
|
/// returns true if a battery failsafe has ever been triggered |
|
bool has_failsafed(void) const { return _has_triggered_failsafe; }; |
|
|
|
/// returns the highest failsafe action that has been triggered |
|
int8_t get_highest_failsafe_priority(void) const { return _highest_failsafe_priority; }; |
|
|
|
/// get_type - returns battery monitor type |
|
enum AP_BattMonitor_Params::BattMonitor_Type get_type() const { return get_type(AP_BATT_PRIMARY_INSTANCE); } |
|
enum AP_BattMonitor_Params::BattMonitor_Type get_type(uint8_t instance) const { return _params[instance].type(); } |
|
|
|
/// true when (voltage * current) > watt_max |
|
bool overpower_detected() const; |
|
bool overpower_detected(uint8_t instance) const; |
|
|
|
// cell voltages |
|
bool has_cell_voltages() { return has_cell_voltages(AP_BATT_PRIMARY_INSTANCE); } |
|
bool has_cell_voltages(const uint8_t instance) const; |
|
const cells & get_cell_voltages() const { return get_cell_voltages(AP_BATT_PRIMARY_INSTANCE); } |
|
const cells & get_cell_voltages(const uint8_t instance) const; |
|
|
|
// temperature |
|
bool get_temperature(float &temperature) const { return get_temperature(temperature, AP_BATT_PRIMARY_INSTANCE); }; |
|
bool get_temperature(float &temperature, const uint8_t instance) const; |
|
|
|
// get battery resistance estimate in ohms |
|
float get_resistance() const { return get_resistance(AP_BATT_PRIMARY_INSTANCE); } |
|
float get_resistance(uint8_t instance) const { return state[instance].resistance; } |
|
|
|
// returns false if we fail arming checks, in which case the buffer will be populated with a failure message |
|
bool arming_checks(size_t buflen, char *buffer) const; |
|
|
|
// sends powering off mavlink broadcasts and sets notify flag |
|
void checkPoweringOff(void); |
|
|
|
// reset battery remaining percentage |
|
bool reset_remaining(uint16_t battery_mask, float percentage); |
|
|
|
static const struct AP_Param::GroupInfo var_info[]; |
|
|
|
void send_serial_batteryGo_param(mavlink_channel_t chan); |
|
|
|
void request_info(void) ; //battgo |
|
void request_history(void) ; //battgo |
|
|
|
protected: |
|
|
|
/// parameters |
|
AP_BattMonitor_Params _params[AP_BATT_MONITOR_MAX_INSTANCES]; |
|
|
|
private: |
|
static AP_BattMonitor *_singleton; |
|
|
|
BattMonitor_State state[AP_BATT_MONITOR_MAX_INSTANCES]; |
|
AP_BattMonitor_Backend *drivers[AP_BATT_MONITOR_MAX_INSTANCES]; |
|
uint32_t _log_battery_bit; |
|
uint8_t _num_instances; /// number of monitors |
|
|
|
void convert_params(void); |
|
|
|
/// returns the failsafe state of the battery |
|
BatteryFailsafe check_failsafe(const uint8_t instance); |
|
void check_failsafes(void); // checks all batteries failsafes |
|
|
|
battery_failsafe_handler_fn_t _battery_failsafe_handler_fn; |
|
const int8_t *_failsafe_priorities; // array of failsafe priorities, sorted highest to lowest priority, -1 indicates no more entries |
|
|
|
int8_t _highest_failsafe_priority; // highest selected failsafe action level (used to restrict what actions we move into) |
|
bool _has_triggered_failsafe; // true after a battery failsafe has been triggered for the first time |
|
|
|
}; |
|
|
|
namespace AP { |
|
AP_BattMonitor &battery(); |
|
};
|
|
|